The Resource Recirculation suction large break LOCA analysis of the Santa Maria De Garoña nuclear power plant using TRAC-BF1 (G1J1), prepared by J.V. López ... [and others]

Recirculation suction large break LOCA analysis of the Santa Maria De Garoña nuclear power plant using TRAC-BF1 (G1J1), prepared by J.V. López ... [and others]

Label
Recirculation suction large break LOCA analysis of the Santa Maria De Garoña nuclear power plant using TRAC-BF1 (G1J1)
Title
Recirculation suction large break LOCA analysis of the Santa Maria De Garoña nuclear power plant using TRAC-BF1 (G1J1)
Statement of responsibility
prepared by J.V. López ... [and others]
Contributor
Subject
Language
eng
Member of
Cataloging source
GPO
Government publication
federal national government publication
Illustrations
illustrations
Index
no index present
Literary form
non fiction
Nature of contents
  • bibliography
  • technical reports
http://library.link/vocab/relatedWorkOrContributorName
  • López, J. V
  • U.S. Nuclear Regulatory Commission
  • Universidad Politécnica de Madrid
Series statement
International agreement report
Series volume
NUREG/IA-0067
http://library.link/vocab/subjectName
  • Boiling water reactors
  • Nuclear reactor accidents
  • Nuclear power plants
Label
Recirculation suction large break LOCA analysis of the Santa Maria De Garoña nuclear power plant using TRAC-BF1 (G1J1), prepared by J.V. López ... [and others]
Instantiates
Publication
Note
  • "Polytechnical University of Madrid."
  • "Prepared as part of the Agreement on Research Participation and Technical Exchange under the International Thermal-Hydraulic Code Assessment and Application Program (ICAP)."
  • Distributed to depository libraries in microfiche
  • Shipping list no.: 93-0872-M
  • "August 1992."
Base of film
safety base undetermined
Bibliography note
Includes bibliographical references (page 16)
Carrier category
microfiche
Carrier category code
he
Carrier MARC source
rdacarrier
Color
black and white
Content category
text
Content type code
txt
Content type MARC source
rdacontent
Control code
17199475
Dimensions
28 cm.
Dimensions
4x6 in. or 11x15 cm.
Emulsion on film
diazo
Extent
xi, 49 pages
Form of item
microfiche
Generation
service copy
Media category
microform
Media MARC source
rdamedia
Media type code
h
Other physical details
illustrations
Positive negative aspect
negative
http://bibfra.me/vocab/marc/reductionRatio
02
ReductionRatioRange
normal reduction
Reproduction note
Microfiche.
Specific material designation
microfiche
Stock number
052-026-00067-9
Label
Recirculation suction large break LOCA analysis of the Santa Maria De Garoña nuclear power plant using TRAC-BF1 (G1J1), prepared by J.V. López ... [and others]
Publication
Note
  • "Polytechnical University of Madrid."
  • "Prepared as part of the Agreement on Research Participation and Technical Exchange under the International Thermal-Hydraulic Code Assessment and Application Program (ICAP)."
  • Distributed to depository libraries in microfiche
  • Shipping list no.: 93-0872-M
  • "August 1992."
Base of film
safety base undetermined
Bibliography note
Includes bibliographical references (page 16)
Carrier category
microfiche
Carrier category code
he
Carrier MARC source
rdacarrier
Color
black and white
Content category
text
Content type code
txt
Content type MARC source
rdacontent
Control code
17199475
Dimensions
28 cm.
Dimensions
4x6 in. or 11x15 cm.
Emulsion on film
diazo
Extent
xi, 49 pages
Form of item
microfiche
Generation
service copy
Media category
microform
Media MARC source
rdamedia
Media type code
h
Other physical details
illustrations
Positive negative aspect
negative
http://bibfra.me/vocab/marc/reductionRatio
02
ReductionRatioRange
normal reduction
Reproduction note
Microfiche.
Specific material designation
microfiche
Stock number
052-026-00067-9

Library Locations

    • Indiana State LibraryBorrow it
      315 W. Ohio St., Indianapolis, IN, 46202, US
      39.77004 -86.164015

Library Links

Processing Feedback ...