The Resource High pressure coolant injection (HPCI) system risk-based inspection guide for Quad-Cities station, units 1 and 2, prepared by M. Villaran, R. Travis, W. Gunther, (microform)

High pressure coolant injection (HPCI) system risk-based inspection guide for Quad-Cities station, units 1 and 2, prepared by M. Villaran, R. Travis, W. Gunther, (microform)

Label
High pressure coolant injection (HPCI) system risk-based inspection guide for Quad-Cities station, units 1 and 2
Title
High pressure coolant injection (HPCI) system risk-based inspection guide for Quad-Cities station, units 1 and 2
Statement of responsibility
prepared by M. Villaran, R. Travis, W. Gunther
Creator
Contributor
Subject
Language
eng
Cataloging source
GPO
http://library.link/vocab/creatorName
Villaran, M
Government publication
federal national government publication
Illustrations
illustrations
Index
no index present
Literary form
non fiction
Nature of contents
  • bibliography
  • technical reports
http://library.link/vocab/relatedWorkOrContributorDate
1948-
http://library.link/vocab/relatedWorkOrContributorName
  • Gunther, W.
  • Travis, R
  • U.S. Nuclear Regulatory Commission
  • Brookhaven National Laboratory
http://library.link/vocab/subjectName
  • Boiling water reactors
  • Nuclear power plants
Type of report
Technical.
Label
High pressure coolant injection (HPCI) system risk-based inspection guide for Quad-Cities station, units 1 and 2, prepared by M. Villaran, R. Travis, W. Gunther, (microform)
Instantiates
Publication
Note
  • "Brookhaven National Laboratory."
  • Distributed to depository libraries in microfiche
  • Shipping list no.: 93-0161-M
  • "Date published: January 1993."
  • "NUREG/CR-5934."
  • "BNL-NUREG-52344."
Base of film
safety base undetermined
Bibliography note
Includes bibliographical references (p. 8-1 - 8-2)
Color
black and white
Control code
17201687
Dimensions
28 cm.
Dimensions
4x6 in. or 11x15 cm.
Emulsion on film
diazo
Extent
1 v. (various pagings)
Form of item
microfiche
Generation
service copy
Other physical details
ill.
Positive negative aspect
negative
http://bibfra.me/vocab/marc/reductionRatio
02
ReductionRatioRange
normal reduction
Reproduction note
Microfiche.
Specific material designation
microfiche
Stock number
052-021-00873-2
Label
High pressure coolant injection (HPCI) system risk-based inspection guide for Quad-Cities station, units 1 and 2, prepared by M. Villaran, R. Travis, W. Gunther, (microform)
Publication
Note
  • "Brookhaven National Laboratory."
  • Distributed to depository libraries in microfiche
  • Shipping list no.: 93-0161-M
  • "Date published: January 1993."
  • "NUREG/CR-5934."
  • "BNL-NUREG-52344."
Base of film
safety base undetermined
Bibliography note
Includes bibliographical references (p. 8-1 - 8-2)
Color
black and white
Control code
17201687
Dimensions
28 cm.
Dimensions
4x6 in. or 11x15 cm.
Emulsion on film
diazo
Extent
1 v. (various pagings)
Form of item
microfiche
Generation
service copy
Other physical details
ill.
Positive negative aspect
negative
http://bibfra.me/vocab/marc/reductionRatio
02
ReductionRatioRange
normal reduction
Reproduction note
Microfiche.
Specific material designation
microfiche
Stock number
052-021-00873-2

Library Locations

    • Indiana State LibraryBorrow it
      315 W. Ohio St., Indianapolis, IN, 46202, US
      39.77004 -86.164015

Library Links

Processing Feedback ...